Pvc and cpvc pipes schedule 40 nominal pipe size inches outside diameter inches minimum wall thickness inches inside diameter inches weight lb ft pvc cpvc 14 14 000 0 438 13 124 11 80 16 16 000 0 500 15 000 15 43 pvc and cpvc pipes schedule 80 nominal pipe size inches outside diameter inches minimum wall thickness inches.
Thin wall pvc pipe specs.
As pvc pipe increases in diameter the walls must also be thicker.
Outer diameter inside diameter and wall diameter as in wall thickness.
Pvc schedule 30 thin wall pipe is for drain waste and vent purposes only.
Fittings are pvc which has good corrosion resistance.
Sdr or class sizes pressurized the second system for sizing pvc pipe is based on the standard dimension ratio a series of ratios of outer diameter to wall thickness.
Below are a series of pvc pipe diagrams and dimension charts to help you find the right sizes or at least get you informed as to the various common sizes.
If the walls were too thin the pipe would lack structural integrity.
4 abs foam core pipe abs schedule 40 dwv pipe for non pressure applications abs 3112 11 2 x 10 031322590 1 900 0 145 27 1 abs 3112 11 2 x 20 031335180 1 900 0 145 27 1 abs 3200 2 x 10 0313416702 375 37 7 0 154.
Usually within 0 25 or just a.
It is for non pressure systems where temperatures will not exceed 140 degrees f.
With thinner walls than schedule 40 fittings these are lighter in weight and have more space on the inside for high flow applications such as underground gravity flow sewer and storm drainage lines.
The requirements of this specification are intended to provide pipe and fittings suitable for drainage of sewage and certain other liquid waste.
It is used in gravity fed waste elimination systems.
To find pvc pipe od sizes you cannot simply add a certain amount to the size on the label.
Pvc pipe sizes dimensions guide charts when it comes to the pvc pipes themselves there are 3 key metrics.
Most pipe is pvc some is cpvc.
Easy online ordering for the ones who get it done along with 24 7 customer service free technical support more.
Most cpvc is also nsf rated and can take up to 180f continous temperatures.
The od for 1 2 pvc pipe is 0 840 and the od for 3 pvc pipe is 3 500.
Pvc schedule 30 thin wall pipe fittings.
Pvc schedule 30 thin wall is lightweight non toxic.
Schedule 40 pvc pipe should not be threaded.
It is commonly used in drainage applications such as.
Wall thickness weight and inner diameter are all approximate and can vary up to 5 unless otherwise noted.
Standard pvc is rated to 140f min.
They are also known as sdr 35 fittings.
If schedule 80 pipe is threaded the working pressure after derating for temperature should be cut in half.
Outside diameter poly vinyl chloride pvc plastic drain waste and vent pipe and fittings scope.
Fittings meet astm d2729 and astm d3034 specifications and testing requirements for material quality.
The outside diameter is held to a much tighter tolerance.